Products / R32 Enjoy Inverter Heating & Cooling

R32 Enjoy Inverter Heating & Cooling

R32 Enjoy Inverter Heating & Cooling

R32 Enjoy models for heating, cooling and hot water, plus a separate higher-output range. Compare model-specific performance, hydraulics and handling data.

Discuss this platform
R32 Enjoy Inverter Heating & Cooling

Catalogue specifications

Develop an R32 heating-and-cooling offer around the Enjoy Series for residential distribution, or a separate higher-output platform for larger hydronic duties. These two model ranges have their own specifications and should be selected against the same market brief.

Enjoy Series for a flexible product portfolio.

  • Five Enjoy models list 5.24 to 18.00 kW seasonal rated heat output at a 35°C water outlet.
  • Confirmed platform ambient range: −25 to 45°C. Catalogue outlet-water range: 5 to 60°C.
  • Heating, cooling and hot-water configurations can serve different distributor applications.
  • Hydraulic modules, circulation equipment and remote-control options are agreed for the selected model.

The grey dual-fan product image represents the Enjoy family. The higher-output range below is a separate model group and is not represented as the same unit.

R32 Enjoy — seasonal heating data
Model Rated heat W35 (kW) SCOP W35 Efficiency W35 Rated heat W55 (kW) SCOP W55 Efficiency W55
RSG-060WBP-1VD 5.24 4.54 178.6% 4.90 3.44 134.6%
RSG-090WBP-1VD 8.96 4.45 175.0% 7.16 3.38 132.2%
RSG-120WBP-1VD 10.07 4.56 179.4% 9.11 3.46 135.4%
RSG-160WBP-1VD 15.75 4.55 179.0% 15.93 3.51 137.4%
RSG-180WBP-1VD 18.00 4.57 180.0% 18.00 3.47 136.0%

Catalogue reference: heating and cooling PDF, spread 5. Seasonal figures are listed for 35°C and 55°C water operation. The catalogue lists A+++ at 35°C and A++ at 55°C; request the matching model-specific documents to review the classification.

R32 Enjoy — configuration and handling
Model Catalogue supply Charge (kg) Flow (m³/h) Drop (kPa) Connection Net (kg) Unit L × W × H (mm) Packing W × D × H (mm)
RSG-060WBP-1VD 220–240V~ / 50–60Hz 1.50 1.03 20 DN25 75 1120 × 418 × 900 1200 × 480 × 1050
RSG-090WBP-1VD 220–240V~ / 50–60Hz 2.00 1.55 20 DN25 80 1120 × 418 × 900 1200 × 480 × 1050
RSG-120WBP-1VD 220–240V~ / 50–60Hz 2.20 2.06 30 DN25 90 1120 × 418 × 900 1200 × 480 × 1050
RSG-160WBP-1VD 220–240V~ / 50–60Hz 2.80 2.75 30 DN25 140 1120 × 418 × 1322 1200 × 480 × 1475
RSG-180WBP-1VD 380–415V / 3N~ / 50–60Hz 3.60 3.10 30 DN25 145 1120 × 418 × 1322 1200 × 480 × 1475

Electrical load, included hydraulic components and final production dimensions are confirmed with the selected model.

R32 Enjoy — cooling capacity at A35 / W7
Model Catalogue cooling modulation range (kW)
RSG-060WBP-1VD 2.00–5.88
RSG-090WBP-1VD 2.96–7.50
RSG-120WBP-1VD 3.50–9.94
RSG-160WBP-1VD 4.94–15.01
RSG-180WBP-1VD 6.05–17.20

A35 / W7 is the catalogue cooling condition: 35°C outdoor air and 7°C water. Request a reviewed performance map for your climate and design water temperatures.

A separate higher-output R32 range.

For a larger system duty, compare the RSG-210 to RSG-450 group separately. Its catalogue seasonal rated heat output at a 35°C outlet spans 21.00 to 45.00 kW. The specified supply is 380–415V / 3N~ / 50–60Hz, and the outlet-water range is 5 to 60°C.

Higher-output R32 — seasonal heating data
Model Rated heat W35 (kW) SCOP W35 Efficiency W35 Rated heat W55 (kW) SCOP W55 Efficiency W55
RSG-210WBP-1VD 21.00 4.57 180.0% 21.00 3.47 136.0%
RSG-240WBP-1VD 22.07 4.60 181.0% 21.10 3.46 135.4%
RSG-300WBP-1VD 25.18 4.58 180.2% 25.35 3.48 136.2%
RSG-350WBP-1VD 35.00 4.58 180.5% 35.00 3.48 136.2%
RSG-450WBP-1VD 45.00 4.58 180.5% 45.00 3.48 136.2%

Catalogue reference: heating and cooling PDF, spread 4. This is a distinct model group; request its model-specific product drawing and compliance scope.

Higher-output R32 — water circuit and handling
Model Charge (kg) Flow (m³/h) Drop (kPa) Connection Net (kg) Unit L × W × H (mm) Packing W × D × H (mm)
RSG-210WBP-1VD 4.00 3.62 30 DN32 155 1120 × 418 × 1422 1200 × 480 × 1575
RSG-240WBP-1VD 3.20 4.13 30 DN32 158 1120 × 418 × 1422 1200 × 480 × 1575
RSG-300WBP-1VD 5.00 5.16 35 DN32 220 1260 × 470 × 1590 1350 × 560 × 1930
RSG-350WBP-1VD 5.80 6.05 35 DN32 220 1260 × 470 × 1590 1350 × 560 × 1930
RSG-450WBP-1VD 7.40 7.78 35 DN32 245 Confirm by model 1350 × 560 × 1930
Higher-output R32 — cooling capacity at A35 / W7
Model Catalogue cooling modulation range (kW)
RSG-210WBP-1VD 7.00–19.80
RSG-240WBP-1VD 8.84–20.58
RSG-300WBP-1VD 9.19–24.64
RSG-350WBP-1VD 10.10–27.70
RSG-450WBP-1VD 13.00–35.70

Specify controls around the partner application.

The catalogue describes local and remote temperature adjustment, timers, mode switching, fault records and cascade management. Confirm the controller, Wi-Fi or DTU module, connectivity and included functions for your market configuration.

Prepare your market-specific product brief.

Tell WOGON your country, supply voltage, climate, application and sales channel. Request the current R32 model sheet, installation information and available model-specific compliance documents for review before an order. Branding, packing, samples, spare parts and supply terms can then be discussed around an agreed scope.

Request a product and document review