R32 Enjoy Inverter Heating & Cooling
R32 Enjoy Inverter Heating & Cooling
R32 Enjoy models for heating, cooling and hot water, plus a separate higher-output range. Compare model-specific performance, hydraulics and handling data.
Discuss this platform
Catalogue specifications
Develop an R32 heating-and-cooling offer around the Enjoy Series for residential distribution, or a separate higher-output platform for larger hydronic duties. These two model ranges have their own specifications and should be selected against the same market brief.
Enjoy Series for a flexible product portfolio.
- Five Enjoy models list 5.24 to 18.00 kW seasonal rated heat output at a 35°C water outlet.
- Confirmed platform ambient range: −25 to 45°C. Catalogue outlet-water range: 5 to 60°C.
- Heating, cooling and hot-water configurations can serve different distributor applications.
- Hydraulic modules, circulation equipment and remote-control options are agreed for the selected model.
The grey dual-fan product image represents the Enjoy family. The higher-output range below is a separate model group and is not represented as the same unit.
| Model | Rated heat W35 (kW) | SCOP W35 | Efficiency W35 | Rated heat W55 (kW) | SCOP W55 | Efficiency W55 |
|---|---|---|---|---|---|---|
| RSG-060WBP-1VD | 5.24 | 4.54 | 178.6% | 4.90 | 3.44 | 134.6% |
| RSG-090WBP-1VD | 8.96 | 4.45 | 175.0% | 7.16 | 3.38 | 132.2% |
| RSG-120WBP-1VD | 10.07 | 4.56 | 179.4% | 9.11 | 3.46 | 135.4% |
| RSG-160WBP-1VD | 15.75 | 4.55 | 179.0% | 15.93 | 3.51 | 137.4% |
| RSG-180WBP-1VD | 18.00 | 4.57 | 180.0% | 18.00 | 3.47 | 136.0% |
Catalogue reference: heating and cooling PDF, spread 5. Seasonal figures are listed for 35°C and 55°C water operation. The catalogue lists A+++ at 35°C and A++ at 55°C; request the matching model-specific documents to review the classification.
| Model | Catalogue supply | Charge (kg) | Flow (m³/h) | Drop (kPa) | Connection | Net (kg) | Unit L × W × H (mm) | Packing W × D × H (mm) |
|---|---|---|---|---|---|---|---|---|
| RSG-060WBP-1VD | 220–240V~ / 50–60Hz | 1.50 | 1.03 | 20 | DN25 | 75 | 1120 × 418 × 900 | 1200 × 480 × 1050 |
| RSG-090WBP-1VD | 220–240V~ / 50–60Hz | 2.00 | 1.55 | 20 | DN25 | 80 | 1120 × 418 × 900 | 1200 × 480 × 1050 |
| RSG-120WBP-1VD | 220–240V~ / 50–60Hz | 2.20 | 2.06 | 30 | DN25 | 90 | 1120 × 418 × 900 | 1200 × 480 × 1050 |
| RSG-160WBP-1VD | 220–240V~ / 50–60Hz | 2.80 | 2.75 | 30 | DN25 | 140 | 1120 × 418 × 1322 | 1200 × 480 × 1475 |
| RSG-180WBP-1VD | 380–415V / 3N~ / 50–60Hz | 3.60 | 3.10 | 30 | DN25 | 145 | 1120 × 418 × 1322 | 1200 × 480 × 1475 |
Electrical load, included hydraulic components and final production dimensions are confirmed with the selected model.
| Model | Catalogue cooling modulation range (kW) |
|---|---|
| RSG-060WBP-1VD | 2.00–5.88 |
| RSG-090WBP-1VD | 2.96–7.50 |
| RSG-120WBP-1VD | 3.50–9.94 |
| RSG-160WBP-1VD | 4.94–15.01 |
| RSG-180WBP-1VD | 6.05–17.20 |
A35 / W7 is the catalogue cooling condition: 35°C outdoor air and 7°C water. Request a reviewed performance map for your climate and design water temperatures.
A separate higher-output R32 range.
For a larger system duty, compare the RSG-210 to RSG-450 group separately. Its catalogue seasonal rated heat output at a 35°C outlet spans 21.00 to 45.00 kW. The specified supply is 380–415V / 3N~ / 50–60Hz, and the outlet-water range is 5 to 60°C.
| Model | Rated heat W35 (kW) | SCOP W35 | Efficiency W35 | Rated heat W55 (kW) | SCOP W55 | Efficiency W55 |
|---|---|---|---|---|---|---|
| RSG-210WBP-1VD | 21.00 | 4.57 | 180.0% | 21.00 | 3.47 | 136.0% |
| RSG-240WBP-1VD | 22.07 | 4.60 | 181.0% | 21.10 | 3.46 | 135.4% |
| RSG-300WBP-1VD | 25.18 | 4.58 | 180.2% | 25.35 | 3.48 | 136.2% |
| RSG-350WBP-1VD | 35.00 | 4.58 | 180.5% | 35.00 | 3.48 | 136.2% |
| RSG-450WBP-1VD | 45.00 | 4.58 | 180.5% | 45.00 | 3.48 | 136.2% |
Catalogue reference: heating and cooling PDF, spread 4. This is a distinct model group; request its model-specific product drawing and compliance scope.
| Model | Charge (kg) | Flow (m³/h) | Drop (kPa) | Connection | Net (kg) | Unit L × W × H (mm) | Packing W × D × H (mm) |
|---|---|---|---|---|---|---|---|
| RSG-210WBP-1VD | 4.00 | 3.62 | 30 | DN32 | 155 | 1120 × 418 × 1422 | 1200 × 480 × 1575 |
| RSG-240WBP-1VD | 3.20 | 4.13 | 30 | DN32 | 158 | 1120 × 418 × 1422 | 1200 × 480 × 1575 |
| RSG-300WBP-1VD | 5.00 | 5.16 | 35 | DN32 | 220 | 1260 × 470 × 1590 | 1350 × 560 × 1930 |
| RSG-350WBP-1VD | 5.80 | 6.05 | 35 | DN32 | 220 | 1260 × 470 × 1590 | 1350 × 560 × 1930 |
| RSG-450WBP-1VD | 7.40 | 7.78 | 35 | DN32 | 245 | Confirm by model | 1350 × 560 × 1930 |
| Model | Catalogue cooling modulation range (kW) |
|---|---|
| RSG-210WBP-1VD | 7.00–19.80 |
| RSG-240WBP-1VD | 8.84–20.58 |
| RSG-300WBP-1VD | 9.19–24.64 |
| RSG-350WBP-1VD | 10.10–27.70 |
| RSG-450WBP-1VD | 13.00–35.70 |
Specify controls around the partner application.
The catalogue describes local and remote temperature adjustment, timers, mode switching, fault records and cascade management. Confirm the controller, Wi-Fi or DTU module, connectivity and included functions for your market configuration.
Prepare your market-specific product brief.
Tell WOGON your country, supply voltage, climate, application and sales channel. Request the current R32 model sheet, installation information and available model-specific compliance documents for review before an order. Branding, packing, samples, spare parts and supply terms can then be discussed around an agreed scope.